← Back to results
Vulnerability record · public intelligence
CVE-2023-4570
HIGH

NI MeasurementLink Python Services Improper Access Restriction vulnerability

Published Oct 5, 2023 · Updated Nov 3, 2026

Severity · CVSSHIGH · Not scored
Known exploitationNot listed
EPSS / likelihood0.32%
QFinch risk scoreNot available

Original summary

Normalized public record · Updated Nov 3, 2026

NI MeasurementLink Python Services Improper Access Restriction vulnerability

Publisher and source text is retained separately from QFinch interpretation.

QFinch assessment

An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the `ni-measurementlink-service` Python package and all previous versions.

Potential impact

An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions.

Evidence: public source records

Affected products

Affected scope reported by the available public evidence
Affected package, product or rangeFix status
Consult the referenced vendor advisory for affected versions.Consult source advisory

Matching a version is only one part of assessing exposure. QFinch has not assessed your environment on this public page.

Remediation

Apply the vendor-supported fixed release or mitigation, then verify the affected component is no longer reachable.

  1. Confirm the affected product and reachable code path exist in your environment.
  2. Apply the vendor-supported patch or mitigation from the primary advisory.
  3. Rescan the exact deployed revision and retain verification evidence.
Review primary references

Evidence coverage

FIRST-EPSSCVE-LIST-V5
SSVC priority
MEDIUM
Confidence
Not available
Aliases
None reported

Scores appear only when corresponding evidence exists. Missing data is never interpreted as zero risk.

Sources and record history

  1. www.ni.com ↗

Record history

Published Oct 5, 2023 · Last refreshed Nov 3, 2026