← Back to results
Vulnerability record · public intelligence
CVE-2020-12001
UNKNOWN

CVE-2020-12001

Published Jun 15, 2020 · Updated Nov 3, 2026

Severity · CVSSUNKNOWN · Not scored
Known exploitationNot listed
EPSS / likelihood11.78%
QFinch risk scoreNot available

Original summary

Normalized public record · Updated Nov 3, 2026

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system an

Publisher and source text is retained separately from QFinch interpretation.

QFinch assessment

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

Evidence: public source records

Affected products

Affected scope reported by the available public evidence
Affected package, product or rangeFix status
Consult the referenced vendor advisory for affected versions.Consult source advisory

Matching a version is only one part of assessing exposure. QFinch has not assessed your environment on this public page.

Remediation

Apply the vendor-supported fixed release or mitigation, then verify the affected component is no longer reachable.

  1. Confirm the affected product and reachable code path exist in your environment.
  2. Apply the vendor-supported patch or mitigation from the primary advisory.
  3. Rescan the exact deployed revision and retain verification evidence.
Review primary references

Evidence coverage

FIRST-EPSSCVE-LIST-V5
SSVC priority
MEDIUM
Confidence
Not available
Aliases
None reported

Scores appear only when corresponding evidence exists. Missing data is never interpreted as zero risk.

Sources and record history

  1. www.us-cert.gov ↗
  2. www.zerodayinitiative.com ↗

Record history

Published Jun 15, 2020 · Last refreshed Nov 3, 2026