Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1609)
Published Mar 8, 2019 · Updated Nov 3, 2026
Original summary
Normalized public record · Updated Nov 3, 2026
Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1609)
Publisher and source text is retained separately from QFinch interpretation.
QFinch assessment
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(2). Nexus 3500 Platform Switches are affected in versions prior to 7.0(3)I7(6). Nexus 3000 Series Switches are affected in versions prior to 7.0(3)I4(9) and 7.0(3)I7(6). Nexus 3600 Platform Switches are affected in versions prior to 7.0(3)F3(5). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), 8.2(3), and 8.3(2). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected in versions prior to 7.0(3)I4(9) and7.0(3)I7(6). Nexus 9500 R-Series Line Cards and Fabric Modules are affected in versions prior to 7.0(3)F3(5).
Evidence: public source recordsAffected products
| Affected package, product or range | Fix status |
|---|---|
| Consult the referenced vendor advisory for affected versions. | Consult source advisory |
Matching a version is only one part of assessing exposure. QFinch has not assessed your environment on this public page.
Remediation
Apply the vendor-supported fixed release or mitigation, then verify the affected component is no longer reachable.
- Confirm the affected product and reachable code path exist in your environment.
- Apply the vendor-supported patch or mitigation from the primary advisory.
- Rescan the exact deployed revision and retain verification evidence.
Evidence coverage
- SSVC priority
- LOW
- Confidence
- Not available
- Aliases
- None reported
Scores appear only when corresponding evidence exists. Missing data is never interpreted as zero risk.