Original summary

Normalized public record · Updated Nov 3, 2026

An issue was discovered in the DICOM Part 10 File Format in the NEMA DICOM Standard 1995 through 2019b and continuing in current implementations. The 128-byte preamble of a DICOM file that complies with this specification can contain arbitrary executable headers for multiple operating systems, including Portable Executable (PE) files for Windows and Executable and Linkable Format (ELF) files for Linux-based systems. This space is left unspecified so that dual-purpose files can be created. For example, dual-purpose TIFF/DICOM files are used in digital whole slide imaging applications in medicin

Publisher and source text is retained separately from QFinch interpretation.

QFinch assessment

An issue was discovered in the DICOM Part 10 File Format in the NEMA DICOM Standard 1995 through 2019b and continuing in current implementations. The 128-byte preamble of a DICOM file that complies with this specification can contain arbitrary executable headers for multiple operating systems, including Portable Executable (PE) files for Windows and Executable and Linkable Format (ELF) files for Linux-based systems. This space is left unspecified so that dual-purpose files can be created. For example, dual-purpose TIFF/DICOM files are used in digital whole slide imaging applications in medicine. This design flaw enables system-wide compromise as malicious DICOM files are routinely shared between medical devices and hospital systems and transported via removable media for patient care coordination. To exploit this vulnerability, someone must execute the maliciously crafted file. These files can be executable even with the .dcm file extension. Anti-malware configurations at healthcare facilities often ignore medical imagery. DICOM files exist on systems that process protected health information, and successful exploitation could result in violations of regulatory compliance requirements such as HIPAA and FDA postmarket obligations.

Evidence: public source records

Affected products

Affected scope reported by the available public evidence
Affected package, product or rangeFix status
Consult the referenced vendor advisory for affected versions.Consult source advisory

Matching a version is only one part of assessing exposure. QFinch has not assessed your environment on this public page.

Remediation

Apply the vendor-supported fixed release or mitigation, then verify the affected component is no longer reachable.

  1. Confirm the affected product and reachable code path exist in your environment.
  2. Apply the vendor-supported patch or mitigation from the primary advisory.
  3. Rescan the exact deployed revision and retain verification evidence.
Review primary references

Evidence coverage

FIRST-EPSSCVE-LIST-V5
SSVC priority
MEDIUM
Confidence
Not available
Aliases
None reported

Scores appear only when corresponding evidence exists. Missing data is never interpreted as zero risk.

Sources and record history

  1. labs.cylera.com ↗
  2. Source repository ↗
  3. Source repository ↗
  4. 108730 ↗
  5. www.praetorian.com ↗

Record history

Published May 2, 2019 · Last refreshed Nov 3, 2026