Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that any malicious user connecting to the device can change the default SSID and password thereby denying the owner an access to his/her own device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures
Publisher and source text is retained separately from QFinch interpretation.
QFinch assessment
Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that any malicious user connecting to the device can change the default SSID and password thereby denying the owner an access to his/her own device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries.
Evidence: public source recordsAffected products
| Affected package, product or range | Fix status |
|---|---|
| Consult the referenced vendor advisory for affected versions. | Consult source advisory |
Matching a version is only one part of assessing exposure. QFinch has not assessed your environment on this public page.
Remediation
Apply the vendor-supported fixed release or mitigation, then verify the affected component is no longer reachable.
- Confirm the affected product and reachable code path exist in your environment.
- Apply the vendor-supported patch or mitigation from the primary advisory.
- Rescan the exact deployed revision and retain verification evidence.
Evidence coverage
- SSVC priority
- LOW
- Confidence
- Not available
- Aliases
- None reported
Scores appear only when corresponding evidence exists. Missing data is never interpreted as zero risk.